Topic: 改良日新水冷控温,內置改為外置

  Print this page

改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:22

你部日生水冷機是否著機唔夠5~10分鐘又熄機,主缸水[$#28201]未達要求溫度!
部機一個鐘頭又著又熄三~四次的話,試將控溫探頭移到主缸,效果有夠大改善。
但需注意舊探頭位封孔要小心做好防漏!

材料:
1.熱縮通大細各一條。
2.薄膠片一塊,約$1蚊[$#38134]大。
3.AB混合快乾膠。
4.兩芯電話線。

先打開全部機身鏍絲及將把手移除,還有出入水處有兩個 O RING。
然後抽起機殼,勿過急,因有兩個套插連在一起,把它全部分離。
只需將水壺上的控頭取出,再焊接電話線(記緊先落熱縮通)延長。看圖

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:23

水溫探頭位置

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:25

打開個蓋取出探頭

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:26

焊接控溫插頭

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:27

焊接控溫插頭-2
預先穿定熱縮通,至焊接延長線

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:29

焊接控溫插頭-4

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:30

焊接控溫插頭-5

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:31

加薄膠片落混合膠封蓋

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:32

固定控溫插頭

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:36

固定控溫探頭於主缸,記緊穿上熱縮通前,在線身加上少許混合膠,然後先熱縮,此接[$#12525]不能放進水裡。

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 00:38

大功告成。

回覆: 改良日新水冷控遄A內置改為外置 Copy to clipboard
Posted by: erickynow
Posted on: 2005-08-12 01:11

請問加D 混合膠有咩用~?

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 07:52

封蓋時用來防漏.
使延長線熱縮通時防水防電線氧化.

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: 白熊
Posted on: 2005-08-12 09:11

多口講句....
如果水泵停左.....咁會點......

回覆: 回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-12 11:14

白熊 wrote:
多口講句....
如果水泵停左.....咁會點......



行虹吸,如果水泵停左無影響

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: Way
Posted on: 2005-08-13 11:30

你條延長線同個探頭係邊度買架?

回覆: 回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-14 00:58

Way wrote:
你條延長線同個探頭係邊度買架?



條延長線只係普通電話線,貪佢多層外皮。
個探頭只係用番原有水冷壺內拆下來的探頭。

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: mrT
Posted on: 2005-08-14 01:24

咁如果無沙缸咪唔改得羅:?)

回覆: 回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-14 21:28

mrT wrote:
咁如果無沙缸咪唔改得羅:?)



唔關有無沙缸事,只是將水冷壺內的探頭改放入主缸,以主缸[$#28201]度為準。

回覆: 回覆: 回覆: 改良日新水冷控遄A內置改為外置 Copy to clipboard
Posted by: 白熊
Posted on: 2005-08-14 22:40

jhontonny wrote:
白熊 wrote:
多口講句....
如果水泵停左.....咁會點......



行虹吸,如果水泵停左無影響




GOOD:^)

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: mrT
Posted on: 2005-08-15 17:10

我意思係........無沙缸d冷水就要入番主缸,咁行虹吸應該點造啊:?)

回覆: 回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2005-08-15 18:39

mrT wrote:
我意思係........無沙缸d冷水就要入番主缸,咁行虹吸應該點造啊:?)



行虹吸做唔到,用個500~800l/h潛水泵推水冷,入出同出水放一頭一尾。
唔明就pm我留電話,我解釋比你知。

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: mrT
Posted on: 2005-08-15 18:56

明晒,thank you:D

回覆: 回覆: 回覆: 回覆: 改良日新水冷控遄A內置改為外置 Copy to clipboard
Posted by: 呀陸
Posted on: 2005-10-12 10:31

白熊 wrote:
jhontonny wrote:
白熊 wrote:
多口講句....
如果水泵停左.....咁會點......



行虹吸,如果水泵停左無影響




GOOD:^)



白熊兄,乜你咁架~知道有d野都吾出聲~ 仲good, 我古個cooler好易結冰架!!!!!!

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: jhontonny
Posted on: 2006-05-03 12:28

請各魚友注意,此post之改動,只適合舊款水冷(出入兩個咀都見到入製冷喉)
新款只有出水口見到製冷喉!

回覆: 改良日新水冷控温,內置改為外置 Copy to clipboard
Posted by: JonathanChan
Posted on: 2006-06-03 04:50

jhontonny wrote:
你部日生水冷機是否著機唔夠5~10分鐘又熄機,主缸水[$#28201]未達要求溫度!
部機一個鐘頭又著又熄三~四次的話,試將控溫探頭移到主缸,效果有夠大改善。
但需注意舊探頭位封孔要小心做好防漏!




我都多口講句其實改個控溫探頭在回入水口,會唔會簡單D, 一樣解決到成日停機問題,唔洗CUT 左條控溫探頭D線。
不過你個IDEA都機新意:D:D (講明DIY麻);)

我地有 在新的聊天室
即時聊天廣播.
Hosted by DownTown®