Topic: 改良日新水冷控温,內置改為外置 |
| 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:22 你部日生水冷機是否著機唔夠5~10分鐘又熄機,主缸水[$#28201]未達要求溫度! 部機一個鐘頭又著又熄三~四次的話,試將控溫探頭移到主缸,效果有夠大改善。 但需注意舊探頭位封孔要小心做好防漏! 材料: 1.熱縮通大細各一條。 2.薄膠片一塊,約$1蚊[$#38134]大。 3.AB混合快乾膠。 4.兩芯電話線。 先打開全部機身鏍絲及將把手移除,還有出入水處有兩個 O RING。 然後抽起機殼,勿過急,因有兩個套插連在一起,把它全部分離。 只需將水壺上的控頭取出,再焊接電話線(記緊先落熱縮通)延長。看圖 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:23 水溫探頭位置 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:25 打開個蓋取出探頭 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:26 焊接控溫插頭 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:27 焊接控溫插頭-2 預先穿定熱縮通,至焊接延長線 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:29 焊接控溫插頭-4 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:30 焊接控溫插頭-5 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:31 加薄膠片落混合膠封蓋 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:32 固定控溫插頭 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:36 固定控溫探頭於主缸,記緊穿上熱縮通前,在線身加上少許混合膠,然後先熱縮,此接[$#12525]不能放進水裡。 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 00:38 大功告成。 | |
| 回覆: 改良日新水冷控遄A內置改為外置 | Copy to clipboard |
|
Posted by: erickynow Posted on: 2005-08-12 01:11 請問加D 混合膠有咩用~? | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 07:52 封蓋時用來防漏. 使延長線熱縮通時防水防電線氧化. | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: 白熊 Posted on: 2005-08-12 09:11 多口講句.... 如果水泵停左.....咁會點...... | |
| 回覆: 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-12 11:14 白熊 wrote: 多口講句.... 如果水泵停左.....咁會點...... 行虹吸,如果水泵停左無影響 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: Way Posted on: 2005-08-13 11:30 你條延長線同個探頭係邊度買架? | |
| 回覆: 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-14 00:58 Way wrote: 你條延長線同個探頭係邊度買架? 條延長線只係普通電話線,貪佢多層外皮。 個探頭只係用番原有水冷壺內拆下來的探頭。 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: mrT Posted on: 2005-08-14 01:24 咁如果無沙缸咪唔改得羅:?) | |
| 回覆: 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-14 21:28 mrT wrote: 咁如果無沙缸咪唔改得羅:?) 唔關有無沙缸事,只是將水冷壺內的探頭改放入主缸,以主缸[$#28201]度為準。 | |
| 回覆: 回覆: 回覆: 改良日新水冷控遄A內置改為外置 | Copy to clipboard |
|
Posted by: 白熊 Posted on: 2005-08-14 22:40 jhontonny wrote: 白熊 wrote: 多口講句.... 如果水泵停左.....咁會點...... 行虹吸,如果水泵停左無影響 GOOD:^) | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: mrT Posted on: 2005-08-15 17:10 我意思係........無沙缸d冷水就要入番主缸,咁行虹吸應該點造啊:?) | |
| 回覆: 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2005-08-15 18:39 mrT wrote: 我意思係........無沙缸d冷水就要入番主缸,咁行虹吸應該點造啊:?) 行虹吸做唔到,用個500~800l/h潛水泵推水冷,入出同出水放一頭一尾。 唔明就pm我留電話,我解釋比你知。 | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: mrT Posted on: 2005-08-15 18:56 明晒,thank you:D | |
| 回覆: 回覆: 回覆: 回覆: 改良日新水冷控遄A內置改為外置 | Copy to clipboard |
|
Posted by: 呀陸 Posted on: 2005-10-12 10:31 白熊 wrote: jhontonny wrote: 白熊 wrote: 多口講句.... 如果水泵停左.....咁會點...... 行虹吸,如果水泵停左無影響 GOOD:^) 白熊兄,乜你咁架~知道有d野都吾出聲~ 仲good, 我古個cooler好易結冰架!!!!!! | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: jhontonny Posted on: 2006-05-03 12:28 請各魚友注意,此post之改動,只適合舊款水冷(出入兩個咀都見到入製冷喉) 新款只有出水口見到製冷喉! | |
| 回覆: 改良日新水冷控温,內置改為外置 | Copy to clipboard |
|
Posted by: JonathanChan Posted on: 2006-06-03 04:50 jhontonny wrote: 你部日生水冷機是否著機唔夠5~10分鐘又熄機,主缸水[$#28201]未達要求溫度! 部機一個鐘頭又著又熄三~四次的話,試將控溫探頭移到主缸,效果有夠大改善。 但需注意舊探頭位封孔要小心做好防漏! 我都多口講句其實改個控溫探頭在回入水口,會唔會簡單D, 一樣解決到成日停機問題,唔洗CUT 左條控溫探頭D線。 不過你個IDEA都機新意:D:D (講明DIY麻);) | |